Key #1 0123456789: ; <=>?@
Key #2 A B C
Key #3 D E F
Key #4 G H I
Key #5 J K L
Key #6 M N O
Key #7 P Q R S
Key #8 T U V
Key #9 W X Y Z [ ù ] ^ _
Key #0 space ! # $ % & * + , - . /
‘A Key Used to move the cursor back one position
‘C’ Key Used to move the cursor forward one position
Only the LCD and VFD Control Station may be used to edit zone names. From the Installer Programming Menu, press the ‘4’ key to edit
the zone names. The Control Station will prompt you for a Zone ID to be programmed. The valid Zone IDs are 1 to 30.
Enter a number corresponding to the Zone ID and press ENTER. Once a valid Zone ID is selected, the control will display the Zone ID
and the current Zone Name with the cursor on the first character. Press the key associated with each character. Each keypress will change
the display to the next character listed for that key. The characters available for editing the Zone Name are as follows:
3.1.4 Edit Zone Names
To exit out of Edit Function Map mode and return the Control Station to the idle state, press the CLEAR key from the
LOCATION prompt. (You may need to press the CLEAR key several times to get to the LOCATION prompt.) An “End
Local Programming” event will not be logged until 255 seconds after you exit programming mode. This is to allow you to
exit and re-enter programming mode repeatedly without logging each one. To force an “End Local Programming” event to
be logged, immediately (i.e.: to have it reported to the Central Station), press and hold the CLEAR key for three seconds.
When programming the value at the last programming location, the Control Station will return to the LOCATION prompt
if the ENTER key is pressed.
If the panel has been programmed from RPM/2 Pro and the Agency Code has been loaded into the panel, then the locations
corresponding to the telephone numbers and account codes will not be editable.
3.1.3.4 Additional Programming Notes
When the location being programmed is a report code (see sections 3.2.10 - 3.2.12) or an attribute field (see sections 3.2.1
- 3.2.3 and 3.2.12 - 3.2.13), the value will be displayed as an “H” followed by two digits. The “H” indicates that this
location is a Hexadecimal field. The valid entries for these locations are “00” through “FF”, where A - F correspond with
10 - 15 respectively. The Control Station display will automatically display the hexadecimal value.
To program one of these locations, enter digits as normal. To display a ‘1’ in the first digit location, you must enter a ‘0’
before the ‘1’, i.e. ‘01’ displays a ‘1’. To enter an A - F, enter a ‘1’ followed by a ‘0’ through ‘5’. For example:
Enter To Get
1-2-3 C3
0-1-2 12
1-8 18
0-1-1-0 1A
1-2 0C
2-1 21
As in programming normal fields, if too many digits are entered, the first digit entered will be discarded. The ENTER, OFF
CANCEL, ‘C’, and CLEAR keys will work the same as described above.
3.1.3.3 Programming Report Codes and Attribute Fields