MOOSE ZXSSD Uživatelská příručka Strana 34

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 52
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 33
34
Loc Default Loc Default
‘A Key Report Code [655] H-19 Comm Test Report Code [674] H-00
‘B’ Key Report Code [656] H-29 AC Fail Report Code [675] H-FA
‘C’ Key Report Code [657] H-49 AC Restore Report Code [676] H-EA
Duress Code [658] H-99 Low Battery Report Code [677] H-F9
Keypad Lockout Code [659] H-00 Battery Restore Code [678] H-E9
Burg Cancel Report Code [660] H-00 Bell Fault Report Code [679] H-00
Quick Arm Report Code [661] H-00 Bell Restore Report [680] H-00
Auto-Arm Code [662] H-00 Comm Restore Report Code [681] H-00
Auto-Arm Failed Code [663] H-00 Memory Error Report Code [682] H-00
Keyswitch Closing Code [664] H-00 Local Program Begin Code [683] H-00
Keyswitch Opening Code [665] H-00 Local Program End Code [684] H-00
Installer/RPM Closing Code [666] H-00 RPM End Report Code [685] H-00
Installer/RPM Opening Code [667] H-00 RPM Denied Report Code [686] H-00
Closing Extended Code [668] H-00 RPM Abort Report Code [687] H-00
Exit Alarm Code [669] H-00 Missing Keypad Code [688] H-00
Recent Closing Code [670] H-00 Restore Keypad Code [689] H-00
Latch Key Supervision Code [671] H-00 RF Jamming Code [690] H-00
User on Premises Code [672] H-00 RF Channel Clear Code [691] H-00
Comm Test Not Norm Code [673] H-00 RF Keyfob Low Battery Code [692] H-00
System Event Report Codes Default Table
‘A Key Report Code 00 to FF Code sent for alarms activated by pressing the Fire panic key.
‘B’ Key Report Code 00 to FF Code sent for alarms activated by pressing the Police panic key.
‘C’ Key Report Code 00 to FF Code sent for alarms activated by pressing the Medical panic key.
Duress Code 00 to FF Code sent for a duress (Authority Level 13) code arm or disarm.
Keypad Lockout Code 00 to FF Code sent when a control station is locked out due to failed passcode attempts.
Burg Cancel Report Code 00 to FF Code sent when an authorized user resets a burglar alarm after reporting and
before the Burglar Bell Cutoff timer expires.
Quick Arm Report Code 00 to FF Code sent when an area is armed using Two-Button or Double Press Arming.
Auto-Arming Code 00 to FF Code sent when armed by scheduled program or Exit Arm.
Auto-Arm Failed Code 00 to FF Code sent when a scheduled arming is aborted or could not be completed.
Keyswitch Closing Code 00 to FF Code sent when an area is armed by keyswitch zone
Keyswitch Opening Code 00 to FF Code sent when an area is disarmed by keyswitch zone.
Installer/RPM Closing Code 00 to FF Code sent when an area is armed by RPM or the installer at a Control Station.
Installer/RPM Opening Code 00 to FF Code sent when an area is disarmed by RPM or the installer at a Control Station.
Closing Extended Code 00 to FF Code sent when the scheduled closing time is extended.
Exit Alarm Code 00 to FF Code sent in addition to a burglar alarm event if the alarm occurs when the exit
time expires.
The following table refers to programming locations 655 through 692:
Item Valid Range Description
Each report code requires a two digit entry. The first digit sets the primary event code and the second digit sets the extended
code. (See Section 3.1.3.3 for Programming Report Codes). If the transmission format is anything other than a Pulsed
format, it is only necessary to program a value other than zero into either digit to enable that event to be reported, the correct
transmitted data is automatically sent.
3.2.12 System Report Codes Description
WWW.DIYALARMFORUM.COM
Zobrazit stránku 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 51 52

Komentáře k této Příručce

Žádné komentáře